        Small current grounding line selection device is designed to solve single-phase grounding fault

        AddTime:2020-07-22 13:50:23   Views:     【 Big Mid Small 】   Print   Close

        In the small current grounding system, single grounding is a common temporary fault, which often occurs in wet and rainy weather. When single-phase grounding occurs, the fault phase to ground voltage decreases and the non fault two-phase phase voltage increases, but the line voltage is still symmetrical, which does not affect the continuous power supply to users. The system can run for 1 ~ 2 hours, which is also the advantage of small current grounding system.

        When single-phase grounding fault occurs, it can automatically extinguish arc and recover insulation in most cases. However, in case of permanent grounding fault, in order to prevent the expansion of fault caused by the rise of non fault phase voltage, the fault line must be determined and removed as soon as possible, which puts forward the problem of single-phase grounding fault line selection. The smr-zn09 series small current grounding line selection device developed by our company can be accurate Find the fault line and upload the information to the background through alarm relay and communication.

        In the operation of small current grounding power grid, when single-phase grounding fault occurs, the operator on duty should handle it calmly. According to the signal, voltmeter indication, weather condition and operation mode, the virtual and real grounding signals are distinguished. And timely report to the superior dispatching and leaders, and make records of relevant phenomena. In judging and processing, the nature and phase of the fault should be identified according to the characteristics of the ground fault. Secondly, it is necessary to consider the power balance and relay protection coordination among different parts during the operation.


        Prev:Installation principle of arc protection probe  Next:Reasons for frequent starting of fault recording device
        Back To Top
        Copyright ? Bao Ding Shi Simaier Electric Co., Ltd. All Rights Reserved  
        日本熟女中文字幕DVD_欧美成人7601AV在线观看_久久精品毛片免费卡
        1. <table id="nohe7"></table>

          <pre id="nohe7"><label id="nohe7"><xmp id="nohe7"></xmp></label></pre>
        2. <table id="nohe7"><option id="nohe7"></option></table>
            <p id="nohe7"><del id="nohe7"><xmp id="nohe7"></xmp></del></p>
            <td id="nohe7"></td>